    DR5200 - 2-Wire / 10GHz Radar (FMCW) Level Meter

    This device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes. It is ideal for measuring the level of corrosive products with its PP or PTFE antenna options.

    Features
    • PP or PTFE Wave Horn antennas for the measurement of corrosive products
    • Modular design: horizontal or vertical position of housing is suitable for almost all installations
    • Optional local display with an integrated 4-button keypad. It is not necessary to remove the housing cover to get access to the keypad.
    • Quick coupling system permits removal of the housing under process conditions and rotation of the housing through 360°
    • Bayonet housing cover permits easy opening and closing of the housing, even after years in service
    • Measuring range up to 30 m / 98.4 ft
    • Converter is backwards compatible with all BM 70x flange systems
    • SIL2-compliant according to IEC 61508 for safety-related systems
    • Each device is calibrated on dedicated calibration rigs before it leaves the factory
    • Universal measurement device for liquids, pastes and slurries

    Specifications


    Measuring system

    Measuring principle

    2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar

    Application range

    Level measurement of liquids, pastes and slurries

    Primary measured value

    Distance and reflection

    Secondary measured value

    Level, volume, mass and flow rate

    Design

    Construction

    The measurement system consists of a measuring sensor (antenna) and a signal converter

    Options

    Integrated LCD display (-20..+60°C/ -4…+140°F); if the ambient temperature is not in these limits, the display switches off automatically

    High-temperature (HT) extension (if the process connection temperature is more than +150°C / +302°F - Metallic Horn antenna only)

    Straight antenna extensions
    Max. Extension length, PTFE Wave Horn antenna: 300mm / 11.8¨; Max. Extension length, Metallic Horn antenna: 1000mm / 39.4¨

    "S" antenna extension
    - only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

    "L" (right angle) antenna extension
    - only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

    Antenna purging system
    - only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

    Heating / cooling system (with or without the antenna purging system)
    - only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

    Signal cable for remote housing version (refer to cable properties in "Electrical connection: Remote device version")

    Weather protection - for the compact version or the antenna housing (remote version). It cannot be ordered after delivery of the device.

    Max. Measuring range

    PTFE and PP Wave Horn antennas:
    20 m / 65.6 ft

    DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):
    10 m / 32.8 ft

    DN150 / DN200 Metallic Horn antennas:
    30 m / 98.4 ft

    Wave Guide antenna:
    6m/ 32.8 ft

    Also depends on the dielectric constant of the product and the installation type. Refer also to "Antenna selection".

    Min. tank height

    1m/ 3.3 ft

    Top dead zone

    Minimum value: Antenna length+antennna extension length+100mm / 3.9¨

    Beam angle (½ angle) of antenna

    PP Wave Horn: 10°

    PTFE Wave Horn: 10°

    Metallic Horn DN80 / 3¨: 16° - used only in stilling wells

    Metallic Horn DN100 / 4¨: 12° - used only in stilling wells

    Metallic Horn DN150 / 6¨: 8°

    Metallic Horn DN200 / 8¨: 6°

    Wave Guide / stilling well: n/a - the radar signal is inside the tube.

    Display and user interface

    Display

    LCD display
    128 × 64 pixels in 8-step greyscale with 4-button keypad

    Interface languages

    3 language pack options (the language is given in the customer order):
    1 English, French German and Italian
    2 English, French,Spanish and Portuguese
    3 English, Chinese (Mandarin), Japanese and Russian

    Measuring accuracy

     

    Resolution

    1mm/ 0.04¨

    Repeatability

    ±1mm/ ±0.04¨

    Accuracy

    Standard: ±10mm / ±0.4¨, when distance < 10 m / 33 ft; ±0.1% of measured distance, when distance > 10 m / 33 ft
    Option: ±5mm/ ±0.2¨, when distance < 10 m / 33 ft; ±0.05% of measured distance, when distance > 10m/ 33 ft

    Reference conditions acc. to EN 61298-1

    Temperature

    +15...+25°C / +59...+77°F

    Pressure

    1013 mbara ±50 mbar / 14.69 psia ±0.73 psi

    Relative air humidity

    60% ±15%

    Target

    Metal plate in an anechoic chamber

    Operating conditions

     

    Temperature

    Ambient temperature

    -40…+80°C/ -40…+176°F
    Ex: see supplementary operating instructions or approval certificates

    Storage temperature

    -50…+85°C/ -58…+185°F
    Process connection temperature
    (higher temperature on request)

    PP Wave Horn antenna:
    -20...+100°C / -4...+212°F

    PTFE Wave Horn antenna:
    -50...+150°C / -58...+302°F

    Metallic Horn antenna / Wave Guide antenna:
    Standard: FKM/FPM (-40…+150°C (+200°C with an HT extension) / -40…+302°F (+392°F with an HT extension));
    Options: Kalrez® 6375 (-20…+150°C (+250°C with an HT extension) / -4…+302°F (+482°F with an HT extension)); PFA (-60°C…+130°C/ -76…+266°F); EPDM (-50...+130°C / -58...+266°F)The process connection temperature must agree with the temperature limits of the gasket material.
    Ex: see supplementary operating instructions or approval certificates 1

    Pressure

    Process pressure

    PP Wave Horn antenna:
    -1…16 barg / -14.5…232 psig. For more data, refer to Pressure ratings on page 18.

    PTFE Wave Horn antenna:
    -1…40 barg / -14.5…580 psig. For more data, refer to Pressure ratings on page 18.

    Metallic Horn antenna / Wave Guide antenna: 
    Standard: -1…40 barg / -14.5…580 psig; subject to the process connection used and the flange temperature. Higher pressure on request.

    Purging system (option)

    Max. 6 barg / 87 psig (higher pressure on request)

    Heating / cooling system (option)

    Max. 6 barg / 87 psig (higher pressure on request)

    Other conditions

     

    Dielectric constant (?r)

    Direct mode: ≥1.8
    TBF mode: ≥1.1
    Refer also to "Technical data: Antenna selection".

    Ingress protection

    IEC 60529: IP 66/67

    NEMA 250: NEMA type 4X (housing) and type 6P (antenna)

    Maximum rate of change

    10 m/min / 32.8 ft/min

    Installation conditions

     

    Process connection size

    The nominal diameter (DN) should be equal to or larger than the antenna diameter.

    Process connection position

    Make sure that there are not any obstructions directly below the process connection for the device. For more data, refer to Installation on page 31.

    Dimensions and weights

    For dimensions and weights data, refer to Dimensions and weights on page 24.

    Materials

     

    Housing

    Standard: Polyester-coated aluminium

    Option: Stainless steel (1.4404 / 316L)

    Antenna options / Wetted materials

    PTFE Wave Horn antenna with a PTFE flange cladding

    PP Wave Horn antenna with a PP jacket/threaded process connection

    Stainless steel (1.4404 / 316L) Metallic Horn antenna with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket

    Stainless steel (1.4404 / 316L) Wave Guide antennas with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket

    Feedthrough

    PP Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PP)

    PTFE Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PTFE)

    Metallic Horn and Wave Guide antennas: Dual process seal system
    - 1st seal: PTFE with O-ring gasket , 2nd seal: Metaglas® with O-ring gasket 2

    Cable gland

    Standard: none

    Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel

    Weather protection (Option)

    Stainless steel (1.4404 / 316L)

    Process connections

     

    Thread

    PP Wave Horn antenna: G 1½; 1½ NPT

    Flange version

    EN

    PTFE Wave Horn antenna: DN50…150 in PN16, PN40

    Metallic Horn and Wave Guide antennas: DN80…200 in PN16, PN40; others on request

    ASME

    PTFE Wave Horn antenna: 2¨…6¨ in 150 lb / 300 lb

    Metallic Horn and Wave Guide antennas: 3¨…8¨ in 150 lb / 300 lb; others on request

    JIS

    PTFE Wave Horn antenna: 50...150A in 10K

    Metallic Horn and Wave Guide antennas: 80…200A in 10K; others on request

    Other

    Others on request

    Electrical connections

     

    Power supply

    Terminals output - Non-Ex / Ex i:
    12…30 VDC; min./max. value for an output of 22mA at the terminal

    Terminals output - Ex d:
    16…36 VDC; min./max. value for an output of 22mA at the terminal

    Maximum current

    22mA

    Current output load

    Non-Ex / Ex i: RL [Ω] ≤ ((Uext -12 V)/22mA). For more data, refer to Minimum power supply voltage on page 17.

    Ex d: RL [Ω] ≤ ((Uext -16 V)/22mA). For more data, refer to Minimum power supply voltage on page 17.

    Cable entry

    Standard: M20×1.5; Option: ½ NPT

    Cable gland

    Standard: none

    Options: M20×1.5 (cable diameter: 6...10mm / 0.2...0.39¨); others are available on request

    Cable entry capacity (terminal)

    0.5…2.5mm²

    Input and output

     

    Output signal

    4…20mA HART® or 3.8…20.5mA acc. to NAMUR NE 43 3

    Resolution

    ±3 µA

    Temperature drift

    Typically 50 ppm/K

    Digital temperature drift

    Max. ±15mm / 0.6¨ for the full temperature range

    Error signal

    High: 22mA; Low: 3.6mA acc. to NAMUR NE 43

     

     

     

     

    Approvals and certification

    CE

    This device fulfils the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark.

    Vibration resistance

    EN 60068-2-64

    Metallic Horn (without antenna extension options): 5Hz to 100Hz: 4g

     

    Metallic Horn, PTFE or PP Wave Horn: 3.5mm up to 8Hz and 10 m/s²: 1g,

     

    8.5 to 2000Hz

     

    Explosion protection

    ATEX
    DEKRA 11ATEX0166 X

    II 1/2 G, 2 G Ex ia IIC T6...T2 Ga/Gb or Ex ia IIC T6...T2 Gb;

    II 1/2 D, 2 D Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X;

    II 1/2 G, 2 G Ex d ia IIC T6...T2 Ga/Gb or Ex d ia IIC T6...T2 Gb;

    II 1/2 D, 2 D Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db IP6X

    IECEx
    IECEx DEK 11.0060 X

    Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb;

    Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X;

    Ex d ia IIC T6...T2 or Ex d ia IIC T6...T2 Gb;

    Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C IP6X

    cFMus - Dual Seal-approved

    NEC 500

    XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6;

    DIP / Cl. II/III / Div. 1 / Gr. EFG / T6;

    IS / Cl. I/II/III / Div. 1 / Gr. ABCDEFG / T6;

    NI / Cl. I / Div. 2 / Gr. ABCD / T6

    NEC 505

    Cl. I / Zone 0 / AEx d [ia] / IIC / T6;

    Cl. I / Zone 0 / AEx ia / IIC / T6;

    Cl. I / Zone 2 / AEx nA [ia] / IIC / T6;

    Hazardous (Classified) locationss, indoor/outdoor Type 4X and 6P, IP66, Dual Seal

    CEC Section 18 (Zone ratings)

    Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0), T6;

    Cl. I, Zone 0, Ex ia, IIC, T6;

    Cl. I, Zone 2, Ex nA, IIC, T6 DIP A21 IP66 TB 95°C

    CEC Section 18 and Annex J (Division ratings)

    Cl. I, Div. 1/2, Gr. ABCD; Cl. II, Gr. EFG; Cl. III, T6;

    NEPSI (pending)

    Ex ia IIC T2~T6 DIP A21 TA IP66;

    Ex d ia IIC T2~T6 DIP A21 TA IP66

    INMETRO (pending)

    Ex ia IIC T6…T2 Ga/Gb

    Ex ia IIIC T90°C Da/Db IP6X

    Ex d [ia Da] IIC T6…T2 Ga/Gb

    Ex tb [ia Da] IIIC T90°C Db IP6X

    Other standards and approvals

    SIL

    Compact version only: SIL 2 - according to EN 61508 and for high/low demand mode operation

    EMC

    Electromagnetic Compatibility Directive 2004/108/EC in conjunction with EN 61326-1 (2006)
    SIL 2-approved devices agree with EN 61326-3-1 (2008) and EN 61326-3-2 (2008)

     

     

     

     

    Radio approvals

    R & TTE
    Radio Equipment and ecommunications Terminal Equipment Directive
    1999/5/EC in conjunction with ESTI EN 302 372 (2006)

    FCC Rules
    Part 15

    Industry Canada
    RSS-210

    LVD

    Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001)

    NAMUR

    NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Laboratory Control Equipment

     

    NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters

     

    NAMUR NE 53 Software and Hardware of Field Devices and Signal Processing Devices with Digital Electronics

     

    NAMUR NE 107 Self-Monitoring and Diagnosis of Field Devices

    CRN

    This certification is applicable for all Canadian provinces and territories.  For more data, refer to the website.

    Construction code

    Metallic Horn and Wave Guide antennas: NACE MR0175 / ISO 15156; NACE MR0103

      
     1 If the process connection temperature is more than 150°C/ 302°F and the device has Kalrez® 6375 or FKM/FPM gaskets, the device will also have an high temperature extension between the converter and the process connection. Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.The process connection temperature must agree with the temperature limits of the gasket ma- terial.
    2 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG
    3 HART® is a registered trademark of the HART Communication Foundation

    该产品由深圳市好色先生APP下载官方电子科技有限公司提供,销售商地址位于深圳市南山区前海路振业国际商务中心1206。请您仔细阅读产品使用说明书,正确使用。

    如果想试用该产品,请本单位:

     

    好色先生APP下载官方电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。有多功能多产品校准器、电能功率校准器、活塞式好色先生下载链接(气体、高压、液体、真空)、多功能电气安全校准器、示波器、频率计、万用表、阻抗好色先生TV免费下载、功率计、LCR数字电桥、音频好色先生TV免费下载、电容测试仪、电感测试仪、安规测试仪、直流电阻测试仪、网络好色先生TV免费下载、频谱仪、任意波形发生器、温度校准仪、数字测温仪、信号发生器、电源、电子负载、综合测试仪、信号源、滤波器测试仪、材料试验机、温度传感器、热像仪、变压器测试仪、噪声源、视频好色先生TV免费下载、过程校准仪、温度巡检仪、超级测温电桥、黑体炉、射频导纳物位开关、多点物位开关、音叉开关、射频导纳连续物位计、雷达液位计、超声波液位计、油中水含量好色先生TV免费下载、液位测量系统、磁致伸缩液位计、非接触固体雷达、压力传感器、过程表、压力变送器、气动控制器、高纯压力开关、隔膜片、冲液表、计量表膜片密封、材料实验机、食品质构仪、硬度实验机、数字测力计、PETPLUS特性粘度仪、布氏光学扫描系统、洛氏布硬度实验机、全自动显微硬度试验机、布氏硬度试验机、电动试验平台、单柱材料试验系统、双柱材料试验系统、浮球活塞好色先生下载链接、船用温度压力校验仪、点位测量系统、超声波开关、油/水界面开关、在线流体检测开关、多点开关、平板开关、浮顶罐溢出保护开关、空气加热器、织物加热套、电加热带、硅橡胶加热毯、圆桶加热器、IBC加热器、气体加热器、灰斗加热系统、自限温电伴热带、恒功率电伴热带、恒功率电伴热带、覆套式电阻加热器、电阻丝、温度控制器、危险环境加热器及控制、复合材料修补仪、真空修补/处理平台、A320升降舵无损检验包;静电放电干扰模拟器、雷击浪涌干扰模拟器、周波跌落模拟器、辐射抗扰度系统、脉冲群干扰模拟器、传导抗扰度测试系统、传导干扰测试系统、辐射干扰测试系统等仪器。 

    扫一扫

    欢迎关注好色先生APP下载官方网站平台

    联系好色先生APP下载官方

    名称:极仪好色先生APP下载官方

    客服电话:0755-23964199,86564199

    E-mail:service@1001718.com

    传真:0755-23964199

    邮编:518052

    Copyright © 2024-2025 深圳市好色先生APP下载官方电子科技有限公司 版权所有网站地图 ICP备案号:粤ICP备15021421号
    极仪好色先生APP下载官方 制作维护

    0755-23964199
    0775-86564199

    微信扫一扫,给我发消息吧

     
    网站地图